Search results for “Glucose Monitoring

About 2 results in articles

Open Access Pub publishes peer-reviewed, free-to-read open-access articles. Showing articles matching Glucose Monitoring — open any to read the full text, or download the PDF or XML.

2 articles

Development of a Model-Based Noninvasive Glucose Monitoring Device for Non-Insulin Dependent People

May 2014 DOI 10.14302/issn.2374-9431.jbd-13-283

Continuous-time glucose monitoring (CGM) effectively improves glucose control, as oppose to infrequent glucose measurements (i.e. using Lancet Meters), by providing frequent blood glucose concentration (BGC) to better associate this variation with changes in behavior. Currently, the most widely used CGM devices rely on a sensor that is inserted invasively under the skin. Because of the invasive nature and also the replacement cost of sensors, the primary users of current CGM devices are insulin dependent people (type 1 and some type 2 diabetics). Most non-insulin dependent diabetics use only lancet glucose measurements. The ultimate goal of this research is the development of CGM technology that overcomes these limitations (i.e. invasive sensors and their cost) in an effort to increase CGM applications among non-insulin dependent people. To meet this objective, this preliminary work has developed a methodology to mathematically infer BGC from measurements of non-invasive input variables which can be thought of as a “virtual” or “soft” sensor approach. In this work virtual sensors are developed and evaluated on 20 subjects using four BGC measurements per day and eight input variables representing meals, activity, stress, and clock time. Up to four weeks of data are collected for each subject. One evaluation consists of 3 days of training and up to 25 days of testing data. The second one consists of one week of training, one week of validation, and 2 weeks of testing data. The third one consists two weeks of training, one week of validation and one week of testing data. Model acceptability is determined on an individual basis based on the fitted correlation to CGM testing data. For 3 day, 1 week, and 2 weeks training studies, 35%, 55% and 65% of the subjects, respectively, met the Acceptability Criteria that we established based on the concept of usefulness.

Review: Non-Invasive Continuous Blood Glucose Measurement Techniques

Jun 2016 DOI 10.14302/issn.2374-9431.jbd-15-647

Diabetes is a metabolic disorder that results in human body due to insulin deficiency, insulin resistance or both. In the management of diabetes, glucose monitoring technology has been used for the last three decades. The aim of this review article is to describe concise and organized information about different techniques of non-invasive continuous blood glucose monitoring. Many research groups have been working to develop wearable sensors for continuous blood glucose monitoring, but at present, there are to our knowledge no commercially successful non-invasive glucose monitors on the market. To achieve an acceptable sensor system, a glucose sensor should have accuracy better than 15mg/dl (0.8 mmol/l). In future development, continuous glucose sensor systems may become predictable, selective, reliable and acceptable for patient use.

Frequently asked questions

Are these articles peer-reviewed?
Yes. Articles published at Open Access Pub go through single-blind peer review (double-blind on request) under an editorial board before publication.
Are the articles free to read?
Yes. Every article is open access — read the full text online for free and download the PDF or XML, with no paywall or subscription.
How do I cite an article?
Use the DOI shown on each result and on the article page; it is the permanent, citable link to the article.
How do I read or download an article?
Click "Read full text" to open the article HTML, or use the PDF / XML buttons on each card to download it.